7.30.10

Updating the firmware or configuration

Series commissioning via the Web server
You can load a firmware or a configuration to the memory card of the drive with the aid of the
Web server (see Updating firmware/configuration on the memory card (Page 411)).
One of the most important applications for the configuration update is the series
commissioning via the duplication of a master configuration. The individual steps are listed in
the following:
Sequence
1. Configure the master machine (STARTER offline and also online).
2. Switch STARTER offline.
3. Execute the "Load to file system" function in the STARTER.
Use the "Save compressed (.zip archive)" option.
4. Download the master configuration via the Web browser on the other drives (cloning).
5. If the know-how protection was not activated in the master configuration, you can now
finely adjust the configuration for the individual drives.
If the know-how protection was activated, you require a password for the fine adjustment
of all parameters on the individual drives that are not listed in the exception list.
Note
You can find detailed information about the following parameters in the SINAMICS
S120/S150 List Manual in Section "Parameters for write protection and know-how
protection":
• Parameters that can be changed with active know-how protection,
• Parameters that can only be read with active know-how protection,
6. Activate the know-how and copy protection for the individual drives, if required.
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
see Section "Parameters with KHP_WRITE_NO_LOCK"
see Section "Parameters with KHP_ACTIVE_READ"
Basic functions
7.30 Web server
459