Siemens SINAMICS S120 Function Manual page 412

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.25 Upgrade the firmware and project
Updating the firmware or configuration
You can update the firmware and a configuration separately via a zip file. The configuration
data must have been zipped via STARTER (using the "Load to file system" function).
Firmware and configuration can also be updated together. For this reason, the "Select file"
field is present twice. The following description refers to the separate update of the firmware
or the configuration:
1. Click the
2. Select the zip file of the new firmware or configuration in a directory of the Web client.
The name of the firmware or the configuration file is then displayed in the "Select file"
field.
The following options are offered for the subsequent update:
3. Select all the required update options by clicking.
4. Click the "Send update data" button.
During the update, a check is made as to whether there is sufficient free space on the
memory card. The state of the drive objects of the Control Unit is also checked.
– As long as the configuration update is running, fault "F01070 project/firmware
– As soon as partition 1 and partition 2 are not consistent with each other, the following
In both cases an entry is made in the diagnostic buffer of the Control Unit.
Note
The firmware download to the memory card can take several minutes.
412
folder icon to the right of the "Select file" field.
Option
Description
No backup
The existing firmware/configuration is not saved before the update.
No test
The firmware/configuration in the downloaded archive is not checked for
consistency.
No reset
A reset of the firmware/configuration is not initiated after the download.
Delete all
All files are deleted on the memory card before the archive is unpacked.
Note: Activate this option only when updating the firmware. Important data
would be destroyed with this option when updating the configuration.
NOTICE: loss of data,
Only the "/install/sinamics" directory and the license key are then retained.
download to the memory card in progress" is output by SINAMICS.
alarm is output "A01073 POWER ON for backup copy to memory card required".