Siemens SINAMICS S120 Function Manual page 118

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Servo control
4.8 Autotuning
Additional settings and displays
Parameter
Adjustment
range
p5271[0...n]
-
r5276
-
r5277
-
p5292
25 %...125%
r5293
-
r5294
-
r5295
-
p5296[0]
1%...300%
p5296[1]
1%...300%
p5297[0]
-210000...210000
rpm
-210000...210000
m/min
p5297[1]
-210000...210000
rpm
-210000...210000
m/min
r5306[0...n]
-
118
Factory
Setting/display
setting
0000 1100
Configuring One Button Tuning The following settings are possible:
bin
Bit 03: Activates speed precontrol
Only relevant for EPOS.
Bit 04: Activates torque precontrol
If EPOS is active, then the torque precontrol from EPOS is
used (p2567).
If EPOS is not active, then the speed/torque precontrol of the
speed controller is used (p1493, p1428, p1429).
Bit 07: Activates voltage precontrol
-
Displays the estimated position controller gain for One Button Tuning
If position control is implemented using a higher-level open-loop con-
trol system, the open-loop control system can assume the values
displayed here.
-
Displays the estimated precontrol symmetrizing time of the position
controller for One Button Tuning
If position control is implemented using a higher-level open-loop con-
trol system, the open-loop control system can assume the values
displayed here.
80%
Dynamic response factor for the P gain of the speed controller.
The speed control may become instable if the values are too high.
-
Display of the determined proportional gain of the speed controller
calculated from the FFT measurement through "One button tuning".
-
Display of the identified mechanical zero positions.
-
Display of the identified mechanical pole positions.
10%
Setting the amplitude of the noise signal for the functions p5301.0 and
p5301.1. The value refers to the rated torque of the motor r0333.
30%
Setting the amplitude of the noise signal for the functions p5301.4 and
p5301.5. The value refers to the rated torque of the motor r0333.
0 rpm
Setting the rotational feed offset for the functions p5301.0 and
p5301.1.
0 m/min
This should prevent non-linear effects, such as backlash or stiction,
influencing the measured values.
0 rpm
Setting the rotational feed offset for the functions p5301.4 and
p5301.5.
0 m/min
This should prevent non-linear effects, such as backlash or stiction,
influencing the measured values.
-
Status display of the auto tuning functions that have been executed.
The display refers to the last action of the p5300 (is therefore not
applicable for Button Tuning).
Function Manual, 11/2017, 6SL3097-4AB00-0BP5