Siemens SINAMICS S120 Function Manual page 438

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
7.30 Web server
However, the following access rights apply for a commissioned drive:
Functions of the Web server
Start page / password input
Diagnostic pages (version overview, DO state, alarms,
diagnostic buffer)
Resetting the fault memory
Uploading trace files
Creating/expanding/removing parameter lists
Reading parameters
Writing and saving parameters
Updating the configuration
Updating the firmware
Loading user-defined pages to the drive
Only those lists may be edited for which the user has the appropriate access right. A default set-
1)
ting applies during creation depending on the user.
These rights can be individually assigned for a parameter list. There is a default setting depending
2)
on the user.
Access rights can be set individually for each user and parameter list in the parameter lists via the
Web server configuration.
Password assignment
For "SINAMICS" and the "Administrator" users, password protection is regulated as follows
by default:
● SINAMICS: No password protection
It is recommended that a password is assigned. This must comprise at least 8 characters.
● Administrator: Password protection (password is not pre-selected.
A password with at least 8 characters must be assigned. If no password has been
assigned, the following warning appears when attempting to login "A09000: Web server
security: Administrator password not set".
After the first commissioning, the passwords for the two users can only be defined or
changed via the STARTER configuration. With the restoration of factory settings, the
passwords are reset to the initial setting (see also Chapter "Assigning a password
(Page 433)").
To change a password, you have to know the existing password.
The password is queried once when the corresponding Web page is called.
438
Access rights
All
SINAMICS
X
X
X
X
X
X
1)
X
2)
X
2)
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Administrator
X
X
X
X
X
1)
X
2)
X
2)
X
X
X
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading