Siemens SINAMICS S120 Function Manual page 645

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Overview of important parameters (see SINAMICS S120/S150 List Manual)
Thermal motor model 1
• r0034
• p0318[0...n]
• p0605[0...n]
• p0611[0...n]
• p0612[0...n]
• p0613[0...n]
• p0615[0...n]
• p0627[0...n]
• p0632[0...n]
• p5350[0...n]
• p5390[0...n]
• p5391[0...n]
Thermal motor model 2
• p0344[0...n]
• p0612[0...n]
• p0617[0...n]
• p0618[0...n]
• p0619[0...n]
• p0625[0...n]
• p0626[0...n]
• p0627[0...n]
• p0628[0...n]
• r0630[0...n]
• r0631[0...n]
• r0632[0...n]
• r0633[0...n]
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
CO: Thermal motor load
Motor stall current
Mot_temp_mod 1/2 threshold and temperature value
I2t motor model thermal time constant
Mot_temp_mod activation
Mot_temp_mod 1/3 ambient temperature
Mot_temp_mod 1 (I2t) fault threshold
Motor overtemperature, stator winding
Mot_temp_mod stator winding temperature
Mot_temp_mod 1/3 zero speed boost factor
Mot_temp_mod 1/3 alarm threshold
Mot_temp_mod 1/3 fault threshold
Motor weight (for thermal motor type)
Mot_temp_mod activation
Stator thermally relevant iron component
Stator thermally relevant copper component
Rotor thermally relevant mass
Motor ambient temperature during commissioning
Motor overtemperature, stator iron
Motor overtemperature, stator winding
Motor overtemperature rotor
Mot_temp_mod ambient temperature
Mot_temp_mod stator iron temperature
Mot_temp_mod stator winding temperature
Mot_temp_mod rotor temperature
Monitoring functions and protective functions
9.5 Thermal motor protection
645

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents