Creating An Encoder Drive Object - Siemens SINAMICS S120 Function Manual

Drive functions
Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

7.23.2

Creating an ENCODER drive object

Creating/inserting an ENCODER drive object is described using a CU320-2 as an example.
In this example, the project is created OFFLINE using the STARTER commissioning tool.
In the project navigator, you can find the selection of the ENCODER drive object between
"Input/output components" and "Drives".
Figure 7-17
Procedure
1. Double-click "Insert encoder".
The "Insert Encoder" dialog box opens.
2. Enter a name for the encoder in the "Name:" input field.
3. Click the "Drive object no." button.
4. Enter a new drive object number in the "Drive object no." input field.
All assigned drive object numbers are shown in the "Assigned drive object no." list.
5. Click "OK".
The configuration window for encoders opens.
6. Select your encoder from the "List of standard encoders", or enter the basis data of the
encoder under "Enter data".
7. Follow the configuration wizard to set-up the encoder.
8. Finally, click the "Finish" button.
The encoder is now inserted into your topology and is available.
Drive functions
Function Manual, 11/2017, 6SL3097-4AB00-0BP5
Project navigator, inserting an "Encoder" drive object
7.23 Creating an encoder as drive object
Basic functions
397