Position
EF
RS485
Fiber optic
NP
1(C24)
LR
1(C15)
NR
1(C24)
LT
1(C15)
NT
1(C24)
LV
1(C15)
NV
1(C24)
E4
G4
EC
1(C15)
GC
1(C15)
EG
1(C15)
GG
1(C15)
E6
G6
ED
1(C15)
GD
1(C15)
EH
1(C15)
GH
1(C15)
EL
GL
EK
GK
EM
GM
EP
1(C15)
GP
1(C15)
EQ
1(C15)
GK
GQ
1(C24)
ER
1(C15)
GR
1(C15)
ET
1(C15)
GT
1(C15)
EU
1(C15)
GU
1(C24)
EV
1(C15)
GV
1(C15)
S6
U6
SD
1(C15)
UD
1(C15)
SH
1(C15)
UH
1(C15)
SL
UL
SP
1(C15)
UP
1(C15)
ST
1(C15)
UT
1(C15)
SM
UM
SR
1(C15)
UR
1(C15)
SV
1(C15)
UV
1(C15)
Note: 'LAN for Local PC' module is determined in 100Base-TX/1000-Base-T, and is
designed for PC engineering tools. It is not designed for Network such as IEC61850,
Number of communication modules
100Base-
1000base-
100Base-TX
FX
/1000Base-T
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
1(C11)
1(C11)
1(C11)
1(C11)
1(C11)
1(C11)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12) 1(C13)†
2(C11,C12) 1(C13)† 1(C15)
2(C11,C12)
2(C11,C12)
2(C11,C12) 1(C13)†
2(C11,C12) 1(C13)† 1(C14)
2(C11,C12)
2(C11,C12)
2(C11,C12) 1(C13)†
2(C11,C12) 1(C13)† 1(C14)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12)
2(C11,C12) 1(C13)
2(C11,C12) 1(C13)
2(C11,C12) 1(C13)
2(C11,C12) 1(C13)
2(C11,C12) 1(C13)
2(C11,C12) 1(C13)
- 955 -
LAN for
IRIG-B
LX
Local PC
1(C15)
1(C15)
1(C15)
1(C15)
1(C13)†
1(C13)† 1(C15)
1(C13)†
1(C13)† 1(C14)
1(C13)†
1(C13)† 1(C14)
1(C13)†
1(C13)† 1(C15)
1(C13)†
1(C13)† 1(C14)
1(C13)†
1(C13)† 1(C14)
1(C13)†
1(C13)† 1(C15)
1(C11)
1(C12)‡
1(C11)
1(C12)‡ 1(C15)
1(C13)†
1(C13)† 1(C14)
1(C11)
1(C12)‡
1(C11)
1(C12)
1(C15)
1(C11)
1(C12)‡ 1(C15)
1(C13)†
1(C13)† 1(C14)
1(C11)
1(C12)‡
1(C11)
1(C12)‡ 1(C15)
1(C13)†
1(C13)† 1(C15)
1(C13)†
1(C13)† 1(C14)
1(C13)†
1(C13)
1(C14)
1(C13)
1(C13)
1(C15)
1(C13)
1(C13)
1(C14)
1(C13)
1(C13)
1(C14)
1(C15)
1(C14)
1(C14)
6F2S1931 (0.20)
Main-Subunit
Redundancy
communication
2(C21,C22) PRP/HSR/RSTP‡
2(C13,C14) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C13,C14) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C13,C14) PRP/HSR/RSTP†
2(C21,C22) PRP/HSR/RSTP†
2(C21,C22)
2(C21,C22)
2(C21,C22)
2(C21,C22)
2(C21,C22)
2(C21,C22)
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C13,C14)
2(C13,C14)
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C13,C14)
2(C13,C14)
2(C13,C14)
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C13,C14)
2(C13,C14)
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) Hot-standby‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
2(C21,C22) PRP/HSR/RSTP‡
Centralized GRB200
(Soft: 030, 031, 032, 033, 034)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grb200

Table of Contents