Toshiba GR200 Series Instruction Manual page 177

Centralized busbar protection ied
Hide thumbs Also See for GR200 Series:
Table of Contents

Advertisement

Signal monitoring point
CBP_OC(Function ID: 458B01)
Element ID
8411101C20
8411111C20
8411121C20
8411131C20
8411141C20
8411151C20
8411161C20
8411171C20
8411181C20
8411191C20
8411201C20
8411211C20
8411221C20
8411231C20
84B0011B70
84B0021B70
84B0031B70
84B0041B70
84B0051B70
84B0061B70
84B0071B70
84B0081B70
84B0091B70
84B0101B70
84B0111B70
84B0121B70
84B0131B70
84B0141B70
84B0151B70
84B0161B70
84B0171B70
84B0181B70
84B0191B70
84B0201B70
84B0211B70
84B0221B70
84B0231B70
84B0241B70
8510001C21
8510011C21
8510021C21
8510031C21
8510041C21
8510051C21
Name
OC2PU_CH11-A
OC2PU_CH12-A
OC2PU_CH13-A
OC2PU_CH14-A
OC2PU_CH15-A
OC2PU_CH16-A
OC2PU_CH17-A
OC2PU_CH18-A
OC2PU_CH19-A
OC2PU_CH20-A
OC2PU_CH21-A
OC2PU_CH22-A
OC2PU_CH23-A
OC2PU_CH24-A
OC2.OPT-A_CH1
OC2.OPT-A_CH2
OC2.OPT-A_CH3
OC2.OPT-A_CH4
OC2.OPT-A_CH5
OC2.OPT-A_CH6
OC2.OPT-A_CH7
OC2.OPT-A_CH8
OC2.OPT-A_CH9
OC2.OPT-A_CH10
OC2.OPT-A_CH11
OC2.OPT-A_CH12
OC2.OPT-A_CH13
OC2.OPT-A_CH14
OC2.OPT-A_CH15
OC2.OPT-A_CH16
OC2.OPT-A_CH17
OC2.OPT-A_CH18
OC2.OPT-A_CH19
OC2.OPT-A_CH20
OC2.OPT-A_CH21
OC2.OPT-A_CH22
OC2.OPT-A_CH23
OC2.OPT-A_CH24
OC2_CH1-B
OC2_CH2-B
OC2_CH3-B
OC2_CH4-B
OC2_CH5-B
OC2_CH6-B
- 163 -
Description
OC2PU_CH11 relay operation level pick up (phase-A)
OC2PU_CH12 relay operation level pick up (phase-A)
OC2PU_CH13 relay operation level pick up (phase-A)
OC2PU_CH14 relay operation level pick up (phase-A)
OC2PU_CH15 relay operation level pick up (phase-A)
OC2PU_CH16 relay operation level pick up (phase-A)
OC2PU_CH17 relay operation level pick up (phase-A)
OC2PU_CH18 relay operation level pick up (phase-A)
OC2PU_CH19 relay operation level pick up (phase-A)
OC2PU_CH20 relay operation level pick up (phase-A)
OC2PU_CH21 relay operation level pick up (phase-A)
OC2PU_CH22 relay operation level pick up (phase-A)
OC2PU_CH23 relay operation level pick up (phase-A)
OC2PU_CH24 relay operation level pick up (phase-A)
OC2_CH1 protection operated (phase-A)
OC2_CH2 protection operated (phase-A)
OC2_CH3 protection operated (phase-A)
OC2_CH4 protection operated (phase-A)
OC2_CH5 protection operated (phase-A)
OC2_CH6 protection operated (phase-A)
OC2_CH7 protection operated (phase-A)
OC2_CH8 protection operated (phase-A)
OC2_CH9 protection operated (phase-A)
OC2_CH10 protection operated (phase-A)
OC2_CH11 protection operated (phase-A)
OC2_CH12 protection operated (phase-A)
OC2_CH13 protection operated (phase-A)
OC2_CH14 protection operated (phase-A)
OC2_CH15 protection operated (phase-A)
OC2_CH16 protection operated (phase-A)
OC2_CH17 protection operated (phase-A)
OC2_CH18 protection operated (phase-A)
OC2_CH19 protection operated (phase-A)
OC2_CH20 protection operated (phase-A)
OC2_CH21 protection operated (phase-A)
OC2_CH22 protection operated (phase-A)
OC2_CH23 protection operated (phase-A)
OC2_CH24 protection operated (phase-A)
OC2_CH1 relay element operated (phase-B)
OC2_CH2 relay element operated (phase-B)
OC2_CH3 relay element operated (phase-B)
OC2_CH4 relay element operated (phase-B)
OC2_CH5 relay element operated (phase-B)
OC2_CH6 relay element operated (phase-B)
6F2S1931 (0.20)
Centralized GRB200
(Soft: 030, 031, 032, 033, 034)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grb200

Table of Contents