No Interface - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Configuration
3.1 System
The placeholder
Type of interface
wlan
wds
vap
vlan
fast-ethernet
The placeholders
For the value ranges for the VLAN logical interface, refer to the upper table. You can only
call up interfaces that you created with the
The ranges of values from the physical interfaces depend on the hardware configuration.
Further notes
You exit the Interface Configuration mode with the
You delete a logical interface with the
You display the status and the configuration of the interfaces with the
command.
3.1.9.6

no interface

Description
With this command, you delete a logical interface.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no interface{vlan<vlan-id(1-4094)>}
The parameters have the following meaning:
Parameter
vlan
vlan-id
Result
The logical interface is deleted.
54
is replaced by the following name of the interface:
$$$
Command prompt
cli(config-if-wlan-0-$)#
cli(config-if-wds$-0-$)#
cli(config-if-vap$-0-$)#
cli(config-if-vlan-$)#
cli(config-if-F-0-$)#
or
denote the numbering of the interface.
$
$-$
no interface
Description
Keyword for a VLAN connection
Number of the addressed VLAN
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
command.
vlan
or
command.
end
exit
command.
Configuration Manual, 10/2015, C79000-G8976-C351-05
show interfaces
Range of values / note
-
1 ... 4094