No Client Config - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Diagnostics
11.1 Diagnostics
11.1.6.3

no client config

Description
With this command, you disable one of the clients that processes or forwards the messages
of the device.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
no client config {syslog|trap|email|all}
The parameters have the following meaning:
Parameter
syslog
trap
email
all
Result
The client selected for the transfer is disabled.
Further notes
You display the status of the events and the clients with the
You enable the function with the
444
Description
Disables the client that sends the messages to the Syslog server
Disables the client that sends the SNMP traps
Disables the client that sends the e-mails
Disables all clients at once
client config
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
show events config
command.
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalance w720Scalance w760

Table of Contents