Network structures
6.3 Spanning Tree
Further notes
You can reset the setting to the default
command.
You can display the status of this function and other information with the
detail
You can display information about active ports with the
command.
6.3.3.4

no spanning-tree compatibility

Description
With this command, you reset the compatibility version of the protocol of the spanning tree
function to the default value.
The default value is MST.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no spanning-tree compatibility
Result
The compatibility version is reset to the default value.
Further notes
You configure the setting with the
You can display the status of this function and other information with the
detail
252
command.
command.
with the
mst
no spanning-tree compatibility
show spanning tree active
spanning-tree compatibility
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
show spanning tree
command.