Option Value-String - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

You delete the DHCP option with the
7.3.3.5

option value-string

Note
The command is only available when the following requirements are met:
• SCALANCE W722-1 RJ45 (article no.: 6GK5722-1FC00-0AA0 and 6GK5722-1FC00-
0AB0 (US version))
• SCALANCE W761-1 RJ45 in access point mode (article number): 6GK5761-1FC00-0AA0
and 6GK5761-1FC00-0AB0 (US version))
• The IPv4 address band is not enabled.
Description
With this command you configure the DHCP option 67 and the name of the boot file as
DHCP parameter. The DHCP option 67 is created automatically when the IPv4 address
band is created.
Requirement
You are in the DHCPPOOL configuration mode.
The command prompt is as follows:
cli(config-dhcp-pool-<ID>)#
Syntax
Call up the command with the following parameters:
option <option-code> value-string <dhcp-param>
The parameters have the following meaning:
Parameter
option-code
dhcp-param
Result
The DHCP option 67 is configured. In total a maximum of 20 DHCP options are possible.
Further notes
You display the setting with the
You delete the DHCP option with the
You configure the DHCP options 3, 6 and 66 with the
You disable the IPv4 address band with the
You configure all other DHCP options with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
no option
Description
Code of the DHCP option
Name of the boot file
show ip dhcp-server pools
no option
command.
Range of values / note
67 - Boot file name
-
command.
command.
command.
option
command.
no pool-enable
command.