Username - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

10.1.4.3

username

Description
With this command, you change the password of the factory set default users "
"
admin
Requirement
● The user is logged in with the "admin" role.
● You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
username {user|admin} password <passwd>
The parameters have the following meaning:
Parameter
user
admin
password
passwd
Result
The password is changed.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
Further notes
You create a user with the
You delete a user with the
You show the created users with the
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
".
Description
User name of the default user with
read access to the configuration
data.
User name of the default user with
read and write access to the con-
figuration data.
Keyword for a password
Value for the password
user-account
no user-account
Range of values / note
Enter "
Enter "
-
Enter the password.
The password must be at least 6 charac-
ters long.
command.
command.
command.
show user-accounts
Security and authentication
10.1 User rights management
" and
user
".
user
".
admin
387