Network structures
6.3 Spanning Tree
6.3.3.14

spanning-tree priority

Description
With this command, you configure the priority of the device. Which device becomes the root
bridge is decided based on the priority. The bridge with the highest priority becomes the root
bridge. The lower the value, the higher the priority.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
spanning-tree[mst <instance-id(1-64)>] priority <value(0-61440)>
The parameters have the following meaning:
Parameter
mst
instance-id
priority
value
You can only change the value for the priority in the steps of 4096.
Result
The priority of the device is configured.
Further notes
You can reset the setting to the default with the
You display this setting and other information with the commands that start with
spanning-tree ...
260
Description
Keyword for a Multiple Spanning Tree
instance
Number of the instance
Keyword for the priority
Value for the priority
.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
-
1 ... 64
-
0 ... 61440
Default: 32768
no spanning-tree priority