Siemens SIMATIC NET Configuration Manual page 110

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Functions specific to SCALANCE
4.5 Spectrum analyzer
The parameter has the following meaning:
Parameter
show-frequencies
frequency
Result
The center frequency is set.
Further notes
You display the settings of the spectrum analyzer with the
command.
110
Description
Shows a list of the selectable center
frequencies.
Center frequency
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
How many channels are displayed
depends on the setting for the "HT
Channel Width", refer to the com-
mand
wlan ht channel width
If you have set the channel band-
width "HT-20", you can choose
between the channels with 20 MHz.
If you have set the channel band-
width "HT40-UP"/"HT-40-DOWN",
you can choose between the chan-
nels with 40 MHz and the following
frequency bands.
In the 5 GHz frequency band:
U-NII-1
U-NII-2A
U-NII-2C/1
U-NII-2C/2
U-NII-3
In the 2.4 GHz frequency band:
2.4 GHz (all)
Select the required frequency or a
frequency band.
show wlan spectrumanalyzer
Configuration Manual, 10/2015, C79000-G8976-C351-05
.