Syntax
Call up the command with the following parameters:
no snmp community index <CommunityIndex>
The parameter has the following meaning:
Parameter
CommunityIndex
Result
The details of an SNMP community are deleted.
Further notes
You configure the details of an SNMP community with the
You show the details of an SNMP community with the
You show the status information of the SNMP communication with the
7.4.2.8

snmp filterprofile

Description
With this command, you configure a filter that describes the access rights to the MIB tree.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Description
Name of the community
Network protocols
Range of values / note
max. 32 characters
snmp community index
command.
show snmp community
show snmp
7.4 SNMP
command.
command.