Event Config - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

11.1.6.4

event config

Description
With this command, you configure which of the various message types of the device will be
stored or forwarded.
The following events or message types are available:
● Message if there is cold or warm restart
● Message when there is a status change on a physical interface
● Message if there is an incorrect login
● Message when there is a status change in the power supply
● Message when there is a status change in the error monitoring
● Message when there is a change in the spanning tree
● Message if radio channels overlap
● Message when changes are made to the connection status of WDS
● Message if a radar signal is received or if there is a status change in the DFS scan.
● Message if the channel bandwidth changes
● Message for successful or failed authentication attempts
● Message if there is a change in the error status (error LED)
● Message when using iPCF.
These messages can be processed by the clients in different ways:
● Entry in the logbook of the device
● Sending the message to the log server of the system
● Sending an e-mail
● Sending an SNMP trap
● Lighting up of the error LED
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli(config-events)#
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface