Advertisement

Network protocols
7.4 SNMP
Parameter
notify
Storage type
The keywords need to be specified.
If optional parameters are not specified when configuring a group, the default value will be
used.
Result
The settings for access to an SNMP group are configured.
Further notes
You delete the access to an SNMP group with the
You display the configured SNMP groups with the
You display the access configurations for SNMP groups with the
command.
You display the configured SNMP tree views with the
7.4.2.5

no snmp access

Description
With this command, you delete the access to an SNMP group.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
snmp access <GroupName>{v1|v2c|v3{auth|noauth|priv}}
334
Description
Changes can be set as a tag
Keyword
specifies whether the settings remain
following a restart
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Range of values / note
NotifyView
none
volatile
The settings are lost after a
restart
nonvolatile
The settings are retained after
a restart
command.
no snmp access
command.
show snmp group
show snmp group access
show snmp viewtree
Configuration Manual, 10/2015, C79000-G8976-C351-05
(volatile):
(non-volatile):
command.