SD54677 $SNS_MEA_CM_MEASURING_ACCURACY[0]
= 0.005
Measurement with rotating spindle: Measured value correction using correction tables
SD54691 $SNS_MEA_T_PROBE_OFFSET
= 0
= 1
= 2
SD54689 $SNS_MEA_T_PROBE_MANUFACTURER
= 0
= 1
= 2
Correction values for users
If the general cycle setting data SD54691 $SNS_MEA_T_PROBE_OFFSET= 2, the following
settings apply:
SD54695 to SD54700
SD54705 to SD54710
SD54695 $SNS_MEA_RESULT_OFFSET_TAB_RAD1[n]
SD54705 $SNS_MEA_RESULT_OFFSET_TAB_LEN1[n]
= 0
= 1
= 2
= 3
= 4
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Default value
No data, default value
Correction in the cycle. This is only effective if
SD54690 $SNS_MEA_T_PROBE_MANUFACTURER>0.
Correction using user-defined correction table
No data, default value
TT130 (Heidenhain)
TS27R (Renishaw)
Correction values for radius
measurement.
Correction values for length
measurement.
0
1. Radius
2. Radius
3. Radius
4. Radius
Configuring cycles
22.8 Measuring cycles and functions
Specified measuring accuracy.
The value of this parameter always
refers to the last probing of the tool
at the probe.
Activates the measuring result
correction
Activate pre-configured compensation
tables for several tool probe models
(customer-specific).
See the subsequent general cycle
setting data.
See the subsequent general cycle
setting data.
Radius measurement
Length measurement
561