SINUMERIK Operate on PC/PCU
24.1
Link OEMFrame application
Integrating an OEM application
The following files should be adapted and created in order to integrate an OEMFrame
application into the operating software:
● Configuration file systemconfiguration.ini
● Configuring the start softkey
● Configuration file "slamconfig.ini"
● Save the language-dependent text for a softkey in the file mytext_<Ing>.ts.
"systemconfiguration.ini" file
In order to integrate an OEMFrame application into the operating software, copy the
"systemconfiguration.ini" configuration file and place it in one of the two directories:
<Installation path>/user/sinumerik/hmi/cfg
<Installation path>/oem/sinumerik/hmi/cfg
All of the processes to be managed by the system manager, as well as the applications that
are to be integrated as OEMFrame applications are in the [processes] section.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
The operating software is started and controlled from the system manager; the system
manager also controls the OEMFrame applications. The system manager is configured
using the "systemconfiguration.ini" configuration file.
In order to start an OEMFrame application from the operating software, configure a
softkey on the expansion bar of the operating area.
In order to configure the softkey position with text and/or symbol for the OEMFrame
application, generate the "slamconfig.ini" file.
24
585