Configuring cycles
22.8 Measuring cycles and functions
SD54672 $SNS_MEA_CM_MAX_FEEDRATE[0]
= 20
SD54673 $SNS_MEA_CM_MIN_FEEDRATE[0]
= 1
SD54674 $SNS_MEA_CM_SPIND_ROT_DIR[0]
4 = M4
Note
If the spindle is already rotating when the measuring cycle is called, this direction of rotation
remains independent of the setting of this data.
SD54675 $SNS_MEA_CM_FEEDFACTOR_1[0]
= 10
= 0
= ≥ 1
SD54676 $SNS_MEA_CM_FEEDFACTOR_2[0]
= 0
= ≥ 1
Note
Feedrate factor 2 should be less than feedrate factor 1.
560
Default value
Default value
Default value
Default value
Only single probing with the feedrate calculated by the cycle. However, as a minimum, the
value from SD54673[0] $SNS_MEA_CM_MIN_FEEDRATE.
First probing with feedrate. However, as a minimum with the value from
SD54673[0] $SNS_MEA_CM_MIN_FEEDRATE)
SD54675[0] $SNS_MEA_CM_FEEDFACTOR_1
Second probing with the feedrate calculated by the cycle. This is only effective for
SD54673 $SNS_MEA_CM_FEEDFACTOR_1[0] > 0, default value.
Second probing with the calculated feedrate from
SD54673 $SNS_MEA_CM_MIN_FEEDRATE[0] feedrate factor 2.
Third probing with the calculated feedrate.
Maximum permissible feedrate to
probe the tool to be measured at the
probe.
Minimum feedrate for the first probing
of the tool to be measured at the
probe. The avoids excessively small
feedrates for large tool radii.
Spindle direction of rotation to
measure tools.
Feedrate factor 1
Feedrate factor 2
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
SINUMERIK Operate (IM9)