Example
[areas]
AREA600= name:=AreaOEM, process:=notepadOEM
AREA601= name:=AreaCalc, process:=calcOEM
Note
Only OEMFrame applications are supported that do not use any of the programming
interfaces of SINUMERIK Operate.
Section [miscellaneous]
You can make various settings in this section. Generally, only the start operating area is
changed.
Key
startuparea
Example
[miscellaneous]
startuparea = AreaOEM
Configuring the operating area menu
The operating area menu is intended for switching over the operating areas configured in the
"systemconfiguration.ini" configuration file. A softkey for selecting the appropriate operating
area is provided on the horizontal softkey bar for each operating area configured.
The operating area displays the names of the operating areas from the
"systemconfiguration.ini" configuration file as the text on the operating area softkeys. The
system automatically searches for a free softkey on the horizontal softkey bar for each
operating area.
Configuring additional settings
In order to configure the following settings you require the "slamconfig.ini" configuration file:
● Assigning a softkey position to a specific operating area.
● Creating a language-dependent text for the softkey.
● Displaying a symbol for the operating area on the softkey.
SINUMERIK Operate (IM9)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
Value
Name of the start operating area
SINUMERIK Operate on PC/PCU
24.1 Link OEMFrame application
587