Examples:
If the control is to synchronize with one of the listed time zones, the examples in the table
can simply be copied.
Zones with daylight saving time/standard time:
Europe:
USA:
Zones without daylight saving time/standard time:
China:
Japan:
Syntax for the time zone description
In order to synchronize with a different time zone, the following syntax applies:
tz offset dst,Mmwd,Mmwd
Syntax (obligatory):
tz offset
Syntax (optional, only if there is daylight saving time):
dst,Mmwd,Mmwd
m (1 ≤ m ≤ 12)
w (1 ≤ w ≤ 5)
d (0 ≤ d ≤ 6)
LogFileLimit
The size of the system logfile
variable. By entering "Zero", the logfile has no size limitations.
The specified limit is no hard limit for reasons of efficiency but rather a sort of limit value. If
the logfile reaches a limit value times factor 1.5, then it is reduced to around 75% of the limit
value. A check is carried out every two minutes maximum to see if the file has become too
large.
Value:
Default:
NCU operating system (IM7)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
WET0WEST,M3.5.0,M10.5.0
CET-1CEST,M3.5.0,M10.5.0
EET-2EEST,M3.5.0,M10.5.0
EST5EDT,M4.1.0,M10.5.0
CST6CDT,M4.1.0,M10.5.0
MST7MDT,M4.1.0,M10.5.0
PST8PDT,M4.1.0,M10.5.0
CST-8
JST-9
Time zone and difference from UTC:
West of the zero meridian, the difference must be added; east of the zero
meridian, the difference should be subtracted.
Daylight saving time zone with beginning and end
m: Month
w: Week of the month, i.e. w = 5 is the last week of the month
d: Day of the week (from 0 = Sunday to 6 = Saturday)
/var/log/messages
Size in KB
100 KB
Configuring the system
2.3 Configuration file "basesys.ini"
can be restricted with the help of this