DisablePLCTimeSync
If this variable is set to 1, synchronization of the system time with the PLC time (in both
directions) will not be executed.
Value:
Default:
EnableCoreDumps
If this variable is set as equal to 1, a logfile for processes is created and stored under
/var/tmp
has terminated.
Value:
Default:
CheckTCUforUpdatePackage
If this variable is set to 1, when booting, the USB interface at the front of the TCU is checked
to identify any storage medium. If, when checking the update packages, type *.usz files
created with Create MyConfig are found, then the installation of these update packages is
started.
With the default setting zero, this check is skipped in order to save time.
Value:
Default:
2.3.8
Example: Configuration file 'basesys.ini'
Configuration file basesys.ini
The following defaults are applied to the template_basesys.ini file which is supplied in the
directory /siemens/system/etc.:
; ------------------------------------------------------------------
; Default Linux basesystem configuration
; ------------------------------------------------------------------
;
; section ID is for Windows compatibility and is ignored ;)
[ExternalInterface]
NCU operating system (IM7)
Commissioning Manual, 03/2013, 6FC5397-1DP40-3BA1
0 or 1
0
. The protocol file contains a memory print of the process that has crashed or that
Empty, 0 or 1
0
0 or 1
0
Configuring the system
2.3 Configuration file "basesys.ini"
29