2.6
Auxiliary function output to the PLC
Function
On output of an auxiliary function to the PLC, the following signals and values are passed to
the NC/PLC interface:
• change signals
• "Address extension" parameter
• "Value" parameter
NC/PLC interface
The change signals and values of the auxiliary functions are within the following data range
in the NC/PLC interface:
• Change signals for auxiliary function transfer from NC channel:
• Transferred M and S functions:
• Transferred T, D and DL functions:
• Transferred H and F functions:
• Decoded M signals (M0 - M99):
References
A detailed description of the NC/PLC interface is to be found in:
/LIS1/ Lists (Book1); signals from/to channel (DB21 – DB30)
The access methods for the NC/PLC interface are described in:
/FB1/ Function Manual, Basic Functions, Basic PLC Program (P3)
Basic logic functions: Auxiliary Function Output to PLC (H2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
DB21, ... DBB58 - DBB67
DB21, ... DBB68 - DBB112
DB21, ... DBB116 - DBB136
DB21, ... DBB140 - DBB190
DB21, ... DBB194 - DBB206 (dynamic M functions)
Detailed description
2.6 Auxiliary function output to the PLC
39