Examples
Activation of workpiece counter $AC_REQUIRED_PARTS
MD27880 $MC_PART_COUNTER = 'H3' (activation of the workpiece counter)
Alarm displayed with: $AC_REQUIRED_PARTS == $AC_SPECIAL_PARTS
Activation of workpiece counter $AC_TOTAL_PARTS
MD27880 $MC_PART_COUNTER = 'H10'
MD27882 $MC_PART_COUNTER_MCODE[0] = 80 (workpiece counting with user-defined M
command)
For each M02: $AC_TOTAL_PARTS += 1
Note: $MC_PART_COUNTER_MCODE[0] has no significance.
Activation of workpiece counter $AC_ACTUAL_PARTS
MD27880 $MC_PART_COUNTER = 'H300'
MD27882 $MC_PART_COUNTER_MCODE[1] = 17
For each M17: $AC_ACTUAL_PARTS += 1
Activation of workpiece counter $AC_SPECIAL_PARTS
MD27880 $MC_PART_COUNTER = 'H3000'
MD27882 $MC_PART_COUNTER_MCODE[2] = 77
For each M77: $AC_SPECIAL_PARTS += 1
Deactivation of workpiece counter $AC_ACTUAL_PARTS
MD27880 $MC_PART_COUNTER = 'H200'
MD27882 $MC_PART_COUNTER_MCODE[1] = 50
Note: $AC_TOTAL_PARTS is not active
Activation of all counters
MD27880 $MC_PART_COUNTER = 'H3313'
MD27882 $MC_PART_COUNTER_MCODE[0] = 80
MD27882 $MC_PART_COUNTER_MCODE[1] = 17
MD27882 $MC_PART_COUNTER_MCODE[2] = 77
Mode change / NC RESET
The counters are not affected by a mode change or NC RESET.
Basic logic functions: Mode group, channel, program operation, reset response (K1)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Detailed description
2.12 Program runtime/workpiece counter
205