Supplementary conditions
3.1
Axis monitoring functions
Settings
For correct operation of the monitoring, the following settings must be made or checked, in
addition to the machine data mentioned:
General
• MD31030 $MA_LEADSCREW_PITCH (Leadscrew pitch)
• MD31050 $MA_DRIVE_AX_RATIO_DENOM (Denominator load gearbox)
• MD31060 $MA_DRIVE_AX_RATIO_NUMERA (Numerator load gearbox)
• MD31070 $MA_DRIVE_ENC_RATIO_DENOM (Denominator measuring gearbox)
• MD31080 $MA_DRIVE_ENC_RATIO_NUMERA (Numerator measuring gearbox)
• MD32810 $MA_EQUIV_SPEEDCTRL_TIME (equivalent time constant speed control loop
• Encoder resolution
Only drives with analog speed setpoint interface
• MD32260 $MA_RATED_VELO (Nominal motor speed)
• MD32250 $MA_RATED_OUTVAL (Nominal output voltage)
Basic logic functions: Axis monitoring, protection zones (A3)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
for feedforward control)
The corresponding machine data is described in:
References:
/FB1/ Function Manual, Basic Functions; Velocities, Setpoint/Actual Value Systems,
Closed-Loop Control (G2)
3
63