Deletion of system frames
The system frames in the data management can be deleted during RESET uisng machine
data:
MD24007 $MC_CHSFRAME_RESET_CLEAR_MASK (deletion of system frames during
RESET)
Bit
0
1
2
3
4
5
6
7
8
9
10
2.4.12.4
Part program start
Frame conditions after part program start
Frame
Programmable frame
Settable frames
Complete basic frame
System frames
External zero offset
DRF offset
Basic logic functions: Axes, coordinate systems, frames (K2)
Function Manual, 11/2006, 6FC5397-0BP10-2BA0
Significance
System frame for actual value setting and scratching is deleted during RESET.
System frame for zero offset external is deleted during RESET.
Reserved, for TCARR and PAROT see MD20150 $MC_GCODE_RESET_VALUES[ ].
Reserved, for TOROT and TOFRAME see MD20150 $MC_GCODE_RESET_VALUES[ ].
System frame for workpiece reference points is deleted during RESET.
System frame for cycles is deleted during RESET.
Reserved, RESET response depends on MD20110 $MC_RESET_MODE_MASK.
System frame for $P_ISO1FR is deleted during RESET.
System frame for $P_ISO2FR is deleted during RESET.
System frame for $P_ISO3FR is deleted during RESET.
System frame for $P_ISO4FR is deleted during RESET.
Condition after parts program start
Deleted.
Retained, depending on:
MD20112 $MC_START_MODE_MASK
Retained
Retained
Retained
Retained
Detailed description
2.4 Frames
133