Sony MSB-2000 Operation Manual page 104

Multi-format stream bridge
Table of Contents

Advertisement

Simple Network Management Protocol (SNMP)
(3.1.1.22) proV1MSBstatusSdiSdtiIn (Read-
Only)
SDI/SDTI Input
Displays the presence or absence of SDI input for "tx-
rx/tx-rx (cm)/sdi_to_asi" mode.
Displays the presence or absence of SDTI-CP input for
"sdti-cp_to_asi" mode.
For any other mode, displays "--------" meaning
"invalid."
(3.1.1.23) proV1MSBstatusAsiIn (Read-Only)
ASI Input
Displays the presence or absence of ASI input for "tx-
rx/tx-rx (cm)/asi_to_sdi/asi_to_sdti-cp " mode.
For any other mode, displays "--------" meaning
"invalid."
(3.1.1.24) proV1MSBstatusCascadeAsiIn
(Read-Only)
Cascade ASI Input
Displays the presence or absence of ASI input for
cascade mux when "cascade mux" is on.
When "cascade mux" is off, displays "--------"
meaning "invalid."
(3.1.1.25) proV1MSBstatusRxCcaption (Read-
Only)
Rx Closed Caption
In asi_to_sdi/asi_to_sdti-cp/tx-rx/tx-rx (cm) mode,
outputs whether or not a private stream to carry closed
captions is included in the selected TS stream being
decoded.
If an input is present this outputs "present", if no input
is present "absent", and in other cases "--------".
(3.1.1.26) proV1MSBstatusVitc (Read-Only)
VITC
In asi_to_sdi/asi_to_sdti-cp/tx-rx/tx-rx (cm) mode,
outputs whether or not a private stream to carry VITC
is included in the selected TS stream being decoded.
If an input is present this outputs "present", if no input
is present "absent", and in other cases "--------".
(3.1.1.27) proV1MSBstatusLinkStatus (Read-
Only)
RTP Link Status
In all modes, displays the connection status of the
MSBA-20IP 100BASE-TX connector.
If connected: "up"
If not connected: "down"
Note that when the MSBA-20IP board is not installed,
"RTP option is not mounted" is output.
(3.1.1.28) proV1MSBstatusLinkSpeed (Read-
Only)
RTP Link Speed
In all modes, when link_status is "up," the
communications speed is displayed, shown as:
For a 10 Mbps connection: "10"
For a 100 Mbps connection: "100"
If link_status is "down," "--------" is output.
Note that when the MSBA-20IP board is not installed,
"RTP option is not mounted" is output.
(3.1.1.29) proV1MSBstatusLinkDuplex (Read-
Only)
RTP Link Duplex
In all modes, when link_status is "up" this shows the
communications mode, as follows:
When link_status is "up" and there is a full-duplex
connection: "full-duplex"
For a half-duplex connection: "half-duplex"
If link_status is "down," "--------" is output.
Note that when the MSBA-20IP board is not installed,
"RTP option is not mounted" is output.
(3.1.1.30) proV1MSBstatusEtherRxPacket
(Read-Only)
RTP Ether Rx Packet
In all modes, the number of Ethernet packets received
by the MSBA-20IP in the most recent one-second
interval is shown.
The maximum output value is "65535." That is to say,
if 65535 or more packets are received in a second, the
output is "65535."
Therefore, the permitted range is never exceeded.
Note that when the MSBA-20IP board is not installed,
"RTP option is not mounted" is output.
(3.1.1.31) proV1MSBstatusEtherRxError
(Read-Only)
RTP Ether Rx Error
In all modes, out of the Ethernet packets received by
the MSBA-20IP in the most recent one-second
interval, the number of packets in which an FEC error
was detected is shown.
The maximum output value is "255." That is to say, if
there were 255 or more error packets in a second, the
output is "255."
Note that when the MSBA-20IP board is not installed,
"RTP option is not mounted" is output.
104

Advertisement

Table of Contents
loading

Table of Contents