3: Default setting 1
Return parameters except for some ones to their default settings.
When you select the setting and press the [OK] key, "Init" blinks in the main area and "Initializing"
appears under it for a while.
They disappear momentarily, the same content displayed at power on appears, and the mode
enters [Standard mode].
The history of past trip data is cleared.
To initialize all parameters, set <tyP: Default setting> to "13".
STOP
0.0Hz
Standard mode
lnit
Initializing...
Easy
Screen
Copy
5-31
15:20
Monitor
5. [Fundamental operation] How to use parameters