Encoder system connection
9.10 Sensor Module External SME120
Cable can be ordered from the manufacturer of the linear scale
1)
Maximum encoder cable length, see diagram in Chapter "Technical data"
2)
Maximum cable length between SME and motor connection: 10 m
3)
Cables are included in the scope of supply of motors without terminal boxes. 6FX8002-2SL0_-... cables are to be used
4)
for motors with 2-hole terminal boxes.
Figure 9-43
Connecting motor encoders via SME for linear motors connected in parallel without a DRIVE-CLiQ interface
9.10.5
Dimension drawing
126,5 (4.98)
73 (2.87)
79,8 (3.14)
Figure 9-44
Dimension drawing of the Sensor Module External SME120, all data in mm and (inches)
296
91,6 (3.61)
117,6 (4.63)
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2