Specifications For Use With Ul Approval - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Hub Modules
7.4 DRIVE-CLiQ Hub Module External DME20
7.4.6

Specifications for use with UL approval

Pre-assembled cables
Sensor/actuator cable, 5-pin, variable cable,
free cable end at straight socket M12-SPEEDCON,
cable length: 2, 5, 10, 15 m
SAC-5P-...-186/FS SCO
Up to 100 m on request
Phoenix Contact
Cables to be assembled by the user
Cable
Cable coil, black PUR/PVC, 5-pin
Conductor colors: brown/white/blue/black/
gray
Cable length: 100 m
SAC-5P-100.0-186/0.75
Article number: 1535590
Phoenix Contact
Power supply
The DME20 must use one of the following 24 V power supplies with voltage limiting:
• SITOP 6EP1x.. or 6ES7307..
• SINAMICS Control Supply Module 6SL3100-1DE22-0A...
Cable pin assignment
Table 7-10
Connection to X524 electronics power supply
Pin
1 (brown)
2
2 (white)
3
5
1
3 (black)
4
4 (blue)
5 (gray)
The colors refer to the cable specified above
1)
212
Designation
Electronics power supply
1)
Electronics power supply
1)
Electronics ground
1)
Electronics ground
1)
Not connected internally
1)
Connector
Sensor/actuator connector, socket, straight, 5-pin,
M12, A-coded
Screw connection, metal knurl,
cable gland Pg9
SACC-M12FS-5CON-PG9-M
Article number: 1681486
Technical data
The supply voltage of 20.4 ... 28.8 V relates to the ter‐
minal voltage at the DME20. This must be taken into
account when selecting the cable cross-section and
supply cable lengths.
Pins 1 and 2: jumpered internally
Pins 3 and 4: jumpered internally
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2

Advertisement

Table of Contents
loading

This manual is also suitable for:

6sl3055-0aa00-5ea

Table of Contents