Interface Description; Overview; Drive-Cliq Interface - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Encoder system connection
9.8 Sensor Module External SME20
9.8.2

Interface description

9.8.2.1

Overview

Figure 9-28
9.8.2.2

DRIVE-CLiQ interface

Table 9-27
Connector
type
Current consumption, maximum 0.25 A
The blanking cover for the DRIVE-CLiQ port to secure the degree of protection IP 67 is not included in the
scope of delivery.
Blanking covers (6 units), article number: 6SL3066-4CA01-0AA0
Note
Only MOTION-CONNECT DRIVE-CLiQ cables may be used for connections. The maximum cable
length is 100 m for MOTION-CONNECT 500, and 75 m for MOTION-CONNECT 800PLUS cables.
276
Interface description SME20
DRIVE-CLiQ interface
Pin
Signal name
1
TXP
2
TXN
3
RXP
4
Reserved, do not use
5
Reserved, do not use
6
RXN
7
Reserved, do not use
8
Reserved, do not use
A
+ (24 V)
B
M (0 V)
DRIVE-CLiQ socket
Technical specifications
Transmit data +
Transmit data -
Receive data +
-
-
Receive data -
-
-
Power supply
Electronics ground
Control Units and additional system components