Encoder system connection
9.10 Sensor Module External SME120
NOTICE
Damage to motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
NOTICE
Overheating of the motor through jumpering the temperature sensor connections
Jumpering temperature sensor connections "+Temp" and "-Temp" results in incorrect
measurement results. Damage to the motor can result if overheating is not detected.
• When using several temperature sensors, separately connect the individual sensors to
9.10.3.4

X300 hall sensor input

Table 9-35
290
"+Temp" and "-Temp".
X300: Hall sensor input
Pin
Signal name
1
C
2
C*
3
P5
4
M
5
D
6
D*
7
Not assigned
8
Not assigned
9
Ground
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Technical data
Absolute track signal C
Inverse absolute track signal C
Encoder power supply
Ground, encoder power supply
Absolute track signal D
Inverse absolute track signal D
-
-
Ground (for internal shield)