Download Print this page

Toshiba GR-200 Series Instruction Manual page 235

Multi functional protection ied
Hide thumbs Also See for GR-200 Series:

Advertisement

Setting
2.19.4
FRQ_MV(Function ID: 475181)
Setting items
FRQ-EN
FRQ
FRQUVBLK
FRQ1-EN
FRQ2-EN
FRQ3-EN
FRQ4-EN
FRQ5-EN
FRQ6-EN
FRQ7-EN
FRQ8-EN
DFRQ1-EN
DFRQ2-EN
DFRQ3-EN
DFRQ4-EN
DFRQ5-EN
DFRQ6-EN
DFRQ7-EN
DFRQ8-EN
FRQ-RCD-EN
FRQ1
FRQ1-Chara
FRQ1
TFRQ1
Output
FRQ1-UseFor
FRQ2
FRQ2-Chara
FRQ2
TFRQ2
Output
FRQ2-UseFor
FRQ3
FRQ3-Chara
FRQ3
TFRQ3
Output
FRQ3-UseFor
FRQ4
FRQ4-Chara
FRQ4
TFRQ4
Output
FRQ4-UseFor
FRQ5
FRQ5-Chara
FRQ5
TFRQ5
Output
FRQ5-UseFor
FRQ6
FRQ6-Chara
FRQ6
TFRQ6
Output
FRQ6-UseFor
FRQ7
FRQ7-Chara
FRQ7
TFRQ7
Output
FRQ7-UseFor
FRQ8
FRQ8-Chara
FRQ8
TFRQ8
Output
FRQ8-UseFor
DFRQ1
DFRQ1-Chara
Range
Unit
Off / On
- FRQ protection enable
40.0 - 100.0
V Voltage level of FRQ protection blocking
Off / On
- FRQ1 protection enable
Off / On
- FRQ2 protection enable
Off / On
- FRQ3 protection enable
Off / On
- FRQ4 protection enable
Off / On
- FRQ5 protection enable
Off / On
- FRQ6 protection enable
Off / On
- FRQ7 protection enable
Off / On
- FRQ8 protection enable
Off / On
- DFRQ1 protection enable
Off / On
- DFRQ2 protection enable
Off / On
- DFRQ3 protection enable
Off / On
- DFRQ4 protection enable
Off / On
- DFRQ5 protection enable
Off / On
- DFRQ6 protection enable
Off / On
- DFRQ7 protection enable
Off / On
- DFRQ8 protection enable
Off / On
- FRQ Rapid Change Detector Scheme enable
OverFrq / UnderFrq
- The selection of FRQ1 character
-10.00 - 10.00
Hz FRQ1 threshold
0.00 - 300.00
s FRQ1 operating delay time
Trip / Alarm
- FRQ1 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ2 character
-10.00 - 10.00
Hz FRQ2 threshold
0.00 - 300.00
s FRQ2 operating delay time
Trip / Alarm
- FRQ2 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ3 character
-10.00 - 10.00
Hz FRQ3 threshold
0.00 - 300.00
s FRQ3 operating delay time
Trip / Alarm
- FRQ3 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ4 character
-10.00 - 10.00
Hz FRQ4 threshold
0.00 - 300.00
s FRQ4 operating delay time
Trip / Alarm
- FRQ4 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ5 character
-10.00 - 10.00
Hz FRQ5 threshold
0.00 - 300.00
s FRQ5 operating delay time
Trip / Alarm
- FRQ5 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ6 character
-10.00 - 10.00
Hz FRQ6 threshold
0.00 - 300.00
s FRQ6 operating delay time
Trip / Alarm
- FRQ6 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ7 character
-10.00 - 10.00
Hz FRQ7 threshold
0.00 - 300.00
s FRQ7 operating delay time
Trip / Alarm
- FRQ7 used for trip or alarm
OverFrq / UnderFrq
- The selection of FRQ8 character
-10.00 - 10.00
Hz FRQ8 threshold
0.00 - 300.00
s FRQ8 operating delay time
Trip / Alarm
- FRQ8 used for trip or alarm
Rise / Down
- The selection of DFRQ1 character
- 216 -
Contents
6F2T0200 (0.15)
Default
Note
Off
40.0
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
UnderFrq
-1.00
1.00
Trip
Down
GRE200 (1,2)

Advertisement

loading

This manual is also suitable for:

Gre200-1Gre200-2