Download Print this page

Toshiba GR-200-5 Instruction Manual page 205

Multi functional protection ied

Advertisement

Signal monitoring point
OVS_MV (Function ID: 461181)
Element ID
8A00031C22
8000031A60
8000031A61
8000031A62
8200031B65
8800031B62
8100031B66
8900031B63
8A00031B64
8000031B23
8200031B60
8800031C24
8900031C25
8A00031C26
8200031B61
8200031BB0
8C00041C20
8D00041C21
8E00041C22
8000041A60
8000041A61
8000041A62
8300041B65
8C00041B62
8100041B66
8D00041B63
8E00041B64
8000041B23
8300041B60
8C00041C24
8D00041C25
8E00041C26
8300041B61
8300041BB0
Connection point on PLC logic
OVS_MV (Function ID: 461181)
Element ID
800001EBB0
810002EBB0
820003EBB0
830004EBB0
Name
Description
OVS3-CA
OVS3 relay element operated (phase-CA)
OVS3-DEF-AB
OVS3 phase_AB def output
OVS3-DEF-BC
OVS3 phase_BC def output
OVS3-DEF-CA
OVS3 phase_CA def output
OVS3-OPT
OVS3 protection operated
OVS3-OPT-AB
OVS3 protection operated (phase-AB)
OVS3-OPT-ALARM
Alarm signal by OVS3 protection
OVS3-OPT-BC
OVS3 protection operated (phase-BC)
OVS3-OPT-CA
OVS3 protection operated (phase-CA)
OVS3-OPT-TRIP
Trip signal by OVS3 protection
OVS3-OR
OVS3 relay element operated (3-phases OR)
OVS3PU-AB
OVS3 relay operation level pick up (phase-AB)
OVS3PU-BC
OVS3 relay operation level pick up (phase-BC)
OVS3PU-CA
OVS3 relay operation level pick up (phase-CA)
OVS3PU-OR
OVS3 relay operation level pick up (3-phases OR)
OVS3_BLOCK
OVS3 protection block command
OVS4-AB
OVS4 relay element operated (phase-AB)
OVS4-BC
OVS4 relay element operated (phase-BC)
OVS4-CA
OVS4 relay element operated (phase-CA)
OVS4-DEF-AB
OVS4 phase_AB def output
OVS4-DEF-BC
OVS4 phase_BC def output
OVS4-DEF-CA
OVS4 phase_CA def output
OVS4-OPT
OVS4 protection operated
OVS4-OPT-AB
OVS4 protection operated (phase-AB)
OVS4-OPT-ALARM
Alarm signal by OVS4 protection
OVS4-OPT-BC
OVS4 protection operated (phase-BC)
OVS4-OPT-CA
OVS4 protection operated (phase-CA)
OVS4-OPT-TRIP
Trip signal by OVS4 protection
OVS4-OR
OVS4 relay element operated (3-phases OR)
OVS4PU-AB
OVS4 relay operation level pick up (phase-AB)
OVS4PU-BC
OVS4 relay operation level pick up (phase-BC)
OVS4PU-CA
OVS4 relay operation level pick up (phase-CA)
OVS4PU-OR
OVS4 relay operation level pick up (3-phases OR)
OVS4_BLOCK
OVS4 protection block command
Name
Description
OVS1_BLOCK
OVS1 protection block command
OVS2_BLOCK
OVS2 protection block command
OVS3_BLOCK
OVS3 protection block command
OVS4_BLOCK
OVS4 protection block command