Commissioning
9.5 Acceptance test
Note
The acceptance is used to check that the safety functions have been correctly
parameterized. The measured values are used to check the plausibility of the
configured safety functions. The measured values that are determined are typical
and are not worst-case values. They represent the behavior of the machine and
the instant in time that the measurement is carried-out. These measurements
cannot be used to derive maximum values for run-on distances.
Authorized person, acceptance report
All SI functions must be acceptance-tested by an authorized person and the test
results recorded in a test report. The report must be signed by the person who car-
ried-out the acceptance tests. The acceptance test report must be kept in the log-
book of the particular machine.
After the SPL has been commissioned the access authorization for the NCK-SPL
(SAFE.SPF) via the HMI interface must be reduced to the manufacturer or service
level and documented in the acceptance report.
An authorized person in the above sense is a person authorized by the machine
manufacturer who on account of his or her technical qualifications and knowledge
of the safety functions has the necessary skill sets to perform the acceptance test
in the correct manner.
Note
S Please refer to the information in Section 9.2, "Procedure when commissioning
for the first time".
S The acceptance report presented below is both an example and
recommendation. The specified values apply to the system chosen for this
particular example.
S Template for the acceptance report:
An electronic template for the acceptance report is available:
– in the toolbox for SINUMERIK 840D sl
– on DOCONCD for SINUMERIK 840D sl
– on the service CD for SINUMERIK 840D sl
S The acceptance report comprises checking the alarm displays and including
the alarm reports in the overall acceptance report. In order to obtain
reproducible and comparable alarm displays, during the acceptance test, MD
10094: $MN_SAFE_ALARM_SUPPRESS_LEVEL must be set to 0 in order to
avoid suppressing alarm outputs.
9-354
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) – 03.2006 Edition