Figure 65 Mounting The Ilp Stepping Plate Assemblies On The Ilp - HP Indigo Division Series Instruction For Use & Installation Instructions

Table of Contents

Advertisement

NOTE:
1.
Release the two ILP feed and exit stepping plate assemblies from the ILP stepping plate
pallet (P/N CA245-01234) by releasing the stepping plates securing bracket.
Use an 6 mm wrench to remove the nuts securing the four screws.
2.
To install the ILP exit stepping plate assembly (Figure 64):
a.
Set the ILP close to its final position.

Figure 65 Mounting the ILP stepping plate assemblies on the ILP

1
Mounting interface
b.
Mount the exit stepping plate assembly next to the ILP exit.
Make sure that the connecting studs (Figure 64) fully insert to the ILP exit wall holes.
Open the assembly cover.
Both stepping plate assemblies are secured to the ILP. They
are not identical. The ILP exit-side stepping plate assembly
has four mounting holes for the ILP exit cover. The ILP input-
side stepping plate assembly does not have these holes. See
Figure 64.
When installing the securing screws for the stepping plate
assemblies, it is recommended to use magnetized balled-end
Allen keys.
CA294-03070 rev 00
Installation Manual
1
page 83 of 153