Figure 48 Electrical cabinet M1 PLC, MPI, and Profibus connections

1
PLC (53A1 - 53A3)
2
Mode selector
3
Memory cartridge
4
Cables cover
5
Communications cable connection to PC
11.
Install the CTNET cables as follows:
Cable
From end point
-
Unidrive 24U0 unwinder web
motor controller 5 pin connection
at UD75 in electrical cabinet M1
-
Electrical cabinet M2 U029
turnbar feed (FX)
-
Electrical cabinet M2 U028 exit
nip feed (FE)
-
Electrical cabinet M2 U027 IMP
engage of PE2 (IP2)
-
Electrical cabinet M2 U026 PE2
feed (FP2)
-
Electrical cabinet M2 U025 IMP
engage of PE1 (IP1)
NOTE:
To end point
Electrical cabinet M2 U029
turnbar feed (FX) controllers 5-pin
connection at UD75
Electrical cabinet M2 U028 exit
nip feed (FE) controllers 5-pin
connection at UD75
Electrical cabinet M2 U027 IMP
engage of PE2 (IP2) controllers 5-
pin connection at UD75
Electrical cabinet M2 U026 PE2
feed (FP2) controllers 5-pin
connection at UD75
Electrical cabinet M2 U025 IMP
engage of PE1 (IP2) controllers 5-
pin connection at UD75
Electrical cabinet M2 U024 PE1
feed (FP1) controllers 5-pin
connection at UD75
All electrical cables are to be routed appropriately under the
floor platform.
CA294-03070 rev 00
Installation Manual
Notes
Green CTNET cable
connects between all
Unidrives from UW to FX
to FE to IP2 to FP2 to IP1
to FP1
-
-
-