Figure 8 Remounting The U-Base Slip Plates - HP Indigo Division Series Instruction For Use & Installation Instructions

Table of Contents

Advertisement

b.
Lay the u-bases on the floor at a distance of 6716 mm (1800+2450+2466 mm
(264.4 ins)) from the wall at the unwinder end and at a distance of 693.0 mm
(27.3 ins) apart (Figure 7).
c.
Measure a distance of XXX mm (XXX ins) from the rear of the u-base to the wall at
the electrical cabinets.

Figure 8 Remounting the u-base slip plates

4
5
4
1
U-base slip plate
2
U-base
3
Grease applied here
d.
Remount the u-base slip plates on the u-bases (Figure 8).
Grease the u-bases before mounting the u-base slip plates.
The grease facilitates easy adjustment during the aligning procedure.
e.
Secure the slip plates with the outer screws.
NOTE:
The inner screws are for adjusting. They move the slip plate
from front to rear a total of 10.0 mm.
4
Securing screws (2)
5
Adjustment screws
CA294-03070 rev 00
Installation Manual
1
2
3
page 26 of 153