Create MyConfig - Topo
6.2 Introduction
● Comparison of topologies
● Assignment of module/component properties, such as component name, OEM-ID etc.
● Specification of criteria (Article No.), which the package compares with the actual properties
of the SINAMICS modules on the machine to be produced (read-out TARGET topology of
the SINAMICS), and reports any impermissible deviations.
● Assignment of the DO variables to modules/components.
● Creation of a user-defined topology based on generic modules. This user-defined topology
can be downloaded directly to the SINAMICS when executing the package.
● Support of a step-by-step commissioning for missing components through deactivation of
these components.
● Use the axis-drive assignment (AAZ) to assign the configured axes to the drives that are
actually being used.
Assignment of DO variables and DO properties
DO variables can be assigned to the modules in Topo. These DO variables provide properties
that can be used for the configuration in Expert when executing the package. In this way, it is
possible to work flexibly in Expert with defined DO variables whose absolute values only apply
during the package runtime on the machine.
SINAMICS modules that do not generate their own DO can be assigned the DO-generating
modules via DO variables (e.g. Sensor Module to Motor Module).
The drive-specific parameters can therefore be stored modularly in a package without
reference to a particular DO number, module number, or slave. The assignment of the
parameters to the topology-specific DOs on the machine is controlled flexibly via the DO
variables, manipulation tasks and step scripts defined in the configuration of the package.
The DRIVE-CLiQ wiring created in Topo and the assignments made for DO variables, DO
names and DO numbers are saved via a deploy function to a comparison (*.ust) or user-defined
topology file (*.utz) which is accessed when a package is executed.