Additional useful notes
NC data
SINAMICS data
Display data
SINUMERIK Integrate Create MyConfig - Diff, Expert, Topo
Operating Manual, 11/2016, A5E36537479B-AD
NC data is manipulated on the basis of the NC archive area.
If a context is not set using CHANDATA(n) , then channel 1 is assumed.
NOTICE:
In the case of multi-channel assignments, make sure that CHANDATA(1) is
set in front of data that is not channel-dependent!
If NC data is to be manipulated, in relation or depending on its old value (e.g.:
Operators +=, *=, etc.), then it must be ensured that this data is also included
in the NC output data
(Consider machine data:
11210 UPLOAD_MD_CHANGES_ONLY and 11212
UPLOAD_CHANGES_ONLY).
In the case of "Source of the data," "Initial state," or "Overall reset," all NC
data is always provided.
When loading an archive to organize the memory, the NC requires certain
machine data that is in the
and CHAN.INI) located in front of INITIAL.INI. Before manipulation, the pack‐
age loads all data from INITIAL.INI to the memory, completes the manipulation
operations and then writes back all the data. All previously existing data is
written back to its old position, both in the INITIAL.INI and in the upload files.
Additional data is attached to the data of INITIAL.INI - and according to
the following rule - also to the data of the upload files:
● NC.OPT, if the identifier starts with $ON
● GLOBAL.INI, if the identifier starts with $MN or $MA
● SCALING.INI, if the identifier starts with $MN or $MA
● CHAN.INI, if the identifier starts with $MN or $MC
If NC data is manipulated, the line checksum is generated and attached to all
data.
Drive data is manipulated, based on the DRV archive area.
Display machine data is saved differently for HMI-Advanced and SINUMERIK
Operate.
HMI-Advanced , data is read from the section: [OPI settings] of the
For
file: "MMC.INI" in the search sequence: HMI_ADV → MMC2 → ADD_ON →
OEM → USER but is only written back to MMC.INI under USER. When deleting
data, this results in a reset to a user-specified value of preceding files in the
search sequence.
SINUMERIK Operate , data is read from the section: [OPI settings]
For
of the file: "hmi_md.ini" in the search sequence: siemens → addon → oem
→ user, but is only written back to hmi_md.ini under user. When deleting
data, this results in a reset to a user-specified value of preceding files in the
search sequence.
upload files (NC.OPT, GLOBAL.IN, SCALING.INI
Create MyConfig - Expert
4.5 Component editor