Signal monitoring point
ARC(Function ID: 4A6001)
Element ID
Name
8100021BB7
ARC2_BLOCK
8100021B6F
ARC2_INIT
8100021BB1
ARC2_MODE-FT
8000021BB0
ARC2_MODE-OFF
8600021BB6
ARC2_MODE-ORG
8400021BB4
ARC2_MODE-S&T
8200021BB2
ARC2_MODE-SPAR
8300021BB3
ARC2_MODE-TPAR
8200021B65
ARC2_ORGAR
8000021B63
ARC2_SPAR
8100021B64
ARC2_TPAR
8200001BB4
ARC_BLOCK
8400001B65
ARC_START
8000011BB8
CB1 F.BRIDGE
8000011BB7
CB1-ARC READY
8500011B6F
CB1_94TT
8800011B62
CB1_BRIDGE
8000011BCD
CB1_MANUAL_CLOSE
8100021BB9
CB2 F.BRIDGE
8100021BB8
CB2-ARC READY
8500021B6B
CB2_94TT
8800021B62
CB2_BRIDGE
8100021BCA
CB2_MANUAL_CLOSE
8200001B6A
EVOLV-FAULT TIME OVER
8300001B64
EXT.ARC_START
8000001BB0
EXT.ARC_START-A
8100001BB1
EXT.ARC_START-B
8200001BB2
EXT.ARC_START-C
8000011BCE
F.CB1_94TT
8100021BCB
F.CB2_94TT
8000011B6D
FT ARC1 UNREADY
8000021B69
FT ARC2 UNREADY
8200011BC2
ORGAR1_COND
8200011BC1
ORGAR1_START
8200011BC4
ORGAR1_SUB_COND
8200011BC3
ORGAR1_SUB_START
8200021BC3
ORGAR2_COND
8200021BC2
ORGAR2_START
8200021BC5
ORGAR2_SUB_COND
8200021BC4
ORGAR2_SUB_START
8000001BB5
RYOP-A
8100001BB6
RYOP-B
8200001BB7
RYOP-C
8400001B6B
SHOT NUMBER OVER
Description
ARC2 block signal
ARC2 initiation
Final trip mode for autoreclose 2
Off mode for autoreclose 2
Original mode for autoreclose 2
Single and three-phase mode for autoreclose 2
Single-phase mode for autoreclose 2
Three-phase mode for autoreclose 2
For original ARC2 operation
For single-phase ARC2 operation
For three-phase ARC2 operation
ARC1 & ARC2 block signal
ARC start by general trip
Forcible bridge signal for CB1
CB1 ready signal for ARC1
Discrepancy trip signal in CB1
CB1 bridge
CB1 manual close signal
Forcible bridge signal for CB2
CB2 ready signal for ARC2
Discrepancy trip signal in CB2
CB2 bridge
CB2 manual close signal
Time over of evolved fault under S&T mode
External ARC operation
External ARC start signal (phase-A)
External ARC start signal (phase-B)
External ARC start signal (phase-C)
Forcible discrepancy trip signal in CB1
Forcible discrepancy trip signal in CB2
Final trip under ARC1 unready condition
Final trip under ARC2 unready condition
For original ARC1 condition
For original ARC1 start
For original ARC1 condition (sub)
For original ARC1 start (sub)
For original ARC2 condition
For original ARC2 start
For original ARC2 condition (sub)
For original ARC2 start (sub)
Relay operation (phase-A)
Relay operation (phase-B)
Relay operation (phase-C)
Shot number over