MMC: 509
DESCRIPTION:
Provides the ability to customize the tone cadence provided from the analog Trunk on a system-
wide basis. There are three(3) types of tones available through this MMC. The control of the tone
cadence may be changed from interrupt tone to continuous tone. Some DCS systems may
require default settings to comply with local operating companies. These tones are mainly used
for performing of Automatic Redial Feature depending on call progress tones on request from
internal users on a Trunk call.
Once busy tone is detected from the Central Office then the call will automatically be released
and will be queued for next trial after expiration of Autoredial Interval Timer (MMC 501).
NOTE: Consult your local Central Officer about cadences of tones to meet specifications if you
encounter any trouble during installation.
FEATURE KEYS
OPTIONS KEY
0
CONTINUOUS TONE
1
INTERRUPT TONE
PROGRAM KEYS
UP & DOWN
KEYPAD
SOFT KEYS
SPK
TONES
BUSY TONE RGBACK TONE DIAL TONE
ACTION
1.
Press TRSF 509
Display shows
2.
Press UP or DOWN key to select tone
Press LEFT soft key and advance to step 3
3.
Press UP or DOWN key to select tone control
Press RIGHT soft key to advance to step 4
OR
Press LEFT soft key to return to step 2
4.
Dial in new value for interrupt times (must be four digits)
Press RIGHT soft key advances cursor
Press LEFT soft key retreats cursor back
If valid entry, system returns to step 2
5.
Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
Used to scroll through options
Used to enter selections
Move cursor left and right
Used to store data and advance to next MMC
CO
TONE CADENCE
DISPLAY
CO BUSY TONE
INTERRUPT TONE
CO RGBACK TONE
CONTINUOUS TONE
CO RGBACK TONE
INTERRUPT TONE
CO RGBACK T: