Siemens G130 List Manual page 57

Hide thumbs Also See for G130:
Table of Contents

Advertisement

Note:
The signal can be displayed as process variable (scaling: 1 = 1 Wh).
This is enabled in p0043.
The display is also reset with p0040 = 1.
If an enable is present in r0043 when the Control Unit powers up, then the value from r0039 is transferred into r0042.
As r0039 serves as a reference signal for r0042, due to format reasons, the process energy display can only process
values of r0039 up to 2147483 kWh. r0039 should also be reset using this value.
p0043
BI: Enable energy usage display / Enab energy usage
VECTOR_G
Can be changed: U, T
Data type: Unsigned32 / Binary
P-Group: Communications
Not for motor type: -
Min
-
Description:
Sets the signal source to enable/reset the process energy display in r0042.
BI: p0043 = 1 signal:
The process energy display is enabled in r0042.
Dependency:
Refer to: r0042
p0045
Display values smoothing time constant / Disp_val T_smooth
VECTOR_G
Can be changed: U, T
Data type: FloatingPoint32
P-Group: -
Not for motor type: -
Min
0.00 [ms]
Description:
Sets the smoothing time constant for the following display values:
SERVO: r0078[1], r0079[1], r0081 (calculated from the quantities smoothed with p0045), r0082[1].
VECTOR: r0063[1], r0068[1], r0080[1], r0082[1].
r0046.0...31
CO/BO: Missing enable sig / Missing enable sig
VECTOR_G
Can be changed: -
Data type: Unsigned32
P-Group: Displays, signals
Not for motor type: -
Min
-
Description:
Display and BICO output for missing enable signals that are preventing the closed-loop drive control from being
commissioned.
Bit field:
Bit
00
01
02
03
04
05
08
09
10
11
12
15
16
17
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Signal name
OFF1 enable missing
OFF2 enable missing
OFF3 enable missing
Operation enable missing
Armature short-circuit / DC braking enable
missing
STOP2 enable missing
Safety enable missing
Infeed enable missing
Ramp-function generator enable missing
Ramp-function generator start missing
Setpoint enable missing
QuickStop enable missing
OFF1 enable internal missing
OFF2 enable internal missing
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
10000.00 [ms]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
1 signal
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
0
Access level: 2
Func. diagram: 4715, 5610,
5730, 6714, 8012
Unit selection: -
Expert list: 1
Factory setting
1.00 [ms]
Access level: 1
Func. diagram: 2634
Unit selection: -
Expert list: 1
Factory setting
-
0 signal
No
No
No
No
No
No
No
No
No
No
No
No
No
No
FP
7954
-
-
-
-
-
-
-
-
-
-
-
-
-
57