Siemens G130 List Manual page 171

Hide thumbs Also See for G130:
Table of Contents

Advertisement

p0422[0...n]
Absolute encoder linear measuring step resolution / Enc abs meas step
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0 [nm]
Description:
Sets the resolution of the absolute position for a linear absolute encoder.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
The serial protocol of an absolute encoder provides the position with a certain resolution (e.g. 100 nm). This value
must be entered here.
p0423[0...n]
Absolute encoder rotary singleturn resolution / Enc abs singleturn
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the number of measuring steps per revolution for a rotary absolute encoder.
The resolution refers to the absolute position.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
p0424[0...n]
Encoder linear zero mark distance / Enc lin ZM_dist
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned16
P-Group: Encoder
Not for motor type: -
Min
0 [mm]
Description:
Sets the distance between two zero marks for a linear encoder.
This information is used for zero mark monitoring.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For distance-coded zero marks this parameter signifies the basic distance.
p0425[0...n]
Encoder rotary zero mark distance / Enc rot dist ZM
VECTOR_G, ENC
Can be changed: C2(4)
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
0
Description:
Sets the distance in pulses between two zero marks for a rotary encoder.
This information is used for zero mark monitoring.
Notice:
This parameter is automatically preassigned for encoders from the encoder list and for identify encoder (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
4294967295 [nm]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
1073741823
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
65535 [mm]
Calculated: -
Dyn. index: EDS, p0140
Unit group: -
Scaling: -
Max
16777215
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
100 [nm]
Access level: 3
Func. diagram: 4704
Unit selection: -
Expert list: 1
Factory setting
8192
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
20 [mm]
Access level: 3
Func. diagram: 4704, 8570
Unit selection: -
Expert list: 1
Factory setting
2048
171