Siemens G130 List Manual page 747

Hide thumbs Also See for G130:
Table of Contents

Advertisement

11
12
13
14
15
Dependency:
Refer to: p6993, p6994, r6997, p6998, p6999
Refer to: A49998
p6993[0...2]
Recorder trigger 2 bit mask / Rec trig 2 mask
VECTOR_G (Rec),
Can be changed: U, T
B_INF (Rec)
Data type: Unsigned32
P-Group: -
Not for motor type: -
Min
0000 hex
Description:
Sets the bit mask for trigger signal 2 (p6994) of the recorder.
Trigger 2.1 is formed by ANDing the signal source in p6994[0] and the bit mask in p6993[0].
Trigger 2.2 is formed by ANDing the signal source in p6994[1] and the bit mask in p6993[1].
Trigger 2.3 is formed by ANDing the signal source in p6994[2] and the bit mask in p6993[2].
Index:
[0] = Trigger 2.1
[1] = Trigger 2.2
[2] = Trigger 2.3
Dependency:
Refer to: p6994
p6994[0...2]
CI: Recorder trigger 2 signal source / Rec trig 2 S_src
VECTOR_G (Rec),
Can be changed: U, T
B_INF (Rec)
Data type: Unsigned32 / Integer32
P-Group: -
Not for motor type: -
Min
-
Description:
Sets the signal source for trigger 2 of the recorder.
Trigger 2.1 is formed by ANDing the signal source in p6994[0] and the bit mask in p6993[0].
Trigger 2.2 is formed by ANDing the signal source in p6994[1] and the bit mask in p6993[1].
Trigger 2.3 is formed by ANDing the signal source in p6994[2] and the bit mask in p6993[2].
Index:
[0] = Trigger 2.1
[1] = Trigger 2.2
[2] = Trigger 2.3
Dependency:
Refer to: p6993
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Data buffering running
Post trigger time running
Data being stored
Data buffer full
Trigger group signal
Yes
Yes
Yes
Yes
Set
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
FFFF FFFF hex
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
No
No
No
No
Not set
Access level: 4
Func. diagram: 8144
Unit selection: -
Expert list: 1
Factory setting
0001 hex
Access level: 4
Func. diagram: 8144
Unit selection: -
Expert list: 1
Factory setting
0
-
-
-
-
-