r4708[0...1]
Trace memory space required / Trace mem required
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the required memory in bytes for the actual parameterization.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
r4709[0...1]
Trace memory space required for measuring functions / Trace mem required
CU_G130_PN,
Can be changed: -
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Displays the required memory in bytes for the actual parameterization.
This applies, if the trace for the measurement functions is used.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4799
p4710[0...1]
Trace trigger condition / Trace Trig_cond
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Integer16
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
1
Description:
Sets the trigger condition for the trace.
Value:
1:
2:
3:
4:
5:
6:
7:
8:
Index:
[0] = Trace 0
[1] = Trace 1
p4711[0...5]
Trace trigger signal / Trace trig_signal
CU_G130_PN,
Can be changed: U, T
CU_G150_PN,
Data type: Unsigned32
CU_G130_DP,
P-Group: Trace and function generator
CU_G150_DP
Not for motor type: -
Min
-
Description:
Selects the trigger signal for the trace.
Index:
[0] = Trace 0 parameter in BICO format
[1] = Trace 1 parameter in BICO format
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
Immediate trace start
Positive edge
Negative edge
Entry to hysteresis band
Leaving hysteresis band
Trigger at bit mask
Start with function generator
Trigger at bit mask with edge
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
8
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
-
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
2
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 0
Factory setting
0