Dependency:
Refer to: p9556
Note:
The shutdown speed has no effect for a value = 0.
SS1: Safe Stop 1
p9561
SI Motion SLS (SG) stop response (Control Unit) / SI Mtn SLS resp
VECTOR_G
Can be changed: U, T
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the stop response for the function "Safely Limited Speed" (SLS).
This setting applies for all SLS limit values.
An input value of less than 5 signifies personnel protection, from 10 and upwards, machine protection.
This parameter can only be used for SINUMERIK Safety Integrated.
For motion monitoring functions integrated in the drive, only a value of 5 is permissible. Other settings result in the
safety message C01711/C30711 with message value 44.
Value:
0:
1:
2:
3:
4:
5:
10:
11:
12:
13:
14:
Dependency:
Refer to: p9531, p9563, p9580
Note:
SLS: Safely Limited Speed / SG: Safely reduced speed
p9562[0...1]
SI Motion SLP (SE) stop response (Control Unit) / SI Mtn SLP Stop CU
VECTOR_G
Can be changed: C2(95)
Data type: Integer16
P-Group: Safety Integrated
Not for motor type: -
Min
0
Description:
Sets the stop response for the function "Safely Limited Position" (SLP).
Value:
0:
1:
2:
3:
4:
10:
11:
12:
13:
14:
Index:
[0] = Limit value SLP1 (SE1)
[1] = Limit value SLP2 (SE2)
Dependency:
Refer to: p9534, p9535
Note:
In the extended sense, a bus failure should be seen here as a communication error in the control signals of the safety
functions (e.g. via PROFIsafe or TM54F).
SLP: Safely Limited Position / SE: Safe software limit switches
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
STOP A
STOP B
STOP C
STOP D
STOP E
Sets the stop response via p9563 (SLS-specific)
STOP A with delayed STO when the bus fails
STOP B with delayed STO when the bus fails
STOP C with delayed STO when the bus fails
STOP D with delayed STO when the bus fails
STOP E with delayed STO when the bus fails
STOP A
STOP B
STOP C
STOP D
STOP E
STOP A with delayed stop response when the bus fails
STOP B with delayed stop response when the bus fails
STOP C with delayed stop response when the bus fails
STOP D with delayed stop response when the bus fails
STOP E with delayed stop response when the bus fails
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
14
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
14
2 Parameters
2.2 List of parameters
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
5
Access level: 3
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
2