p4613[0...n]
Motor temperature sensor 4 sensor type MDS / Temp sens4 typ MDS
VECTOR_G
Can be changed: C2(3), U, T
Data type: Integer16
P-Group: Motor
Not for motor type: -
Min
0
Description:
Sets the sensor type of the fourth temperature sensor for the motor temperature monitoring.
Value:
0:
10:
11:
12:
20:
30:
31:
32:
Dependency:
Refer to: r0458, p0600, p0601
Note:
This parameter is effective only when p0601 = 11.
PTC thermistor: Tripping resistance = 1650 Ohm
Information on using temperature sensors is provided in the following literature:
- hardware description of the appropriate components
- SINAMICS S120 Commissioning Manual
r4620[0...3]
Motor temperature measured / Mot_temp meas
VECTOR_G
Can be changed: -
Data type: FloatingPoint32
P-Group: Displays, signals
Not for motor type: -
Min
- [°C]
Description:
Displays the actual temperature in the motor measured through temperature channels 1 ... 4.
Index:
[0] = Temperature channel 1
[1] = Temperature channel 2
[2] = Temperature channel 3
[3] = Temperature channel 4
Note:
For a value not equal to -200.0 °C, the following applies:
- this temperature display is valid.
- a KTY/PT1000 temperature sensor is connected.
For a value equal to -200.0 °C, the following applies:
- this temperature display is not valid (temperature sensor error).
- a PTC sensor or bimetallic NC contact is connected.
- the temperature sensor evaluation is deactivated (p0600 = 0 or p0601 = 0).
- the sensor channel is deactivated (p460x = 0 or p461x = 0).
r4640[0...95]
Encoder diagnostics state machine / Enc diag stat_ma
VECTOR_G, ENC
Can be changed: -
Data type: Unsigned32
P-Group: Encoder
Not for motor type: -
Min
-
Description:
Displays the encoder diagnostics for the PROFIdrive interface.
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
No sensor
PTC fault
PTC alarm
PTC alarm & timer
KTY84, PT100, PT1000
Bimetallic NC contact fault
Bimetallic NC contact alarm
Bimetallic NC contact alarm & timer
Calculated: -
Dyn. index: MDS, p0130
Unit group: -
Scaling: -
Max
32
Calculated: -
Dyn. index: -
Unit group: 21_1
Scaling: p2006
Max
- [°C]
Calculated: -
Dyn. index: -
Unit group: -
Scaling: -
Max
-
2 Parameters
2.2 List of parameters
Access level: 2
Func. diagram: 8016
Unit selection: -
Expert list: 1
Factory setting
10
Access level: 3
Func. diagram: 8016
Unit selection: p0505
Expert list: 1
Factory setting
- [°C]
Access level: 4
Func. diagram: -
Unit selection: -
Expert list: 1
Factory setting
-
685

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: